Call: 800-974-9422 sales@decavibrator.com
1800 RPM – up to 16,500 Lbf centrifugal force
1 - 12 of 12 | Results Per Page | View | Unit of Measure
1 

Item #

Force Output (Max)

Frequency (Max)

Power Source

Force Output Adjustment

Vibrator Weight

Max. Material in Tapered Portion of Bin

B3-550-1A-4 N/A 550 lb N/A Low - 1,800 (Max @ 60 Hz) - 1,500 (Max @ 50 Hz) N/A Electric AC - 3 Phase 230/460 Volt 60 Hz OR 190/380 Volt 50 Hz N/A Eccentric Weight Adjustment N/A 40 lb N/A 16500 lb
B3-1000-1A-4 N/A 1,000 lb N/A Low - 1,800 (Max @ 60 Hz) - 1,500 (Max @ 50 Hz) N/A Electric AC - 3 Phase 230/460 Volt 60 Hz OR 190/380 Volt 50 Hz N/A Eccentric Weight Adjustment N/A 44 lb N/A 30000 lb
B3-2300-2A-4 N/A 2,300 lb N/A Low - 1,800 (Max @ 60 Hz) - 1,500 (Max @ 50 Hz) N/A Electric AC - 3 Phase 230/460 Volt 60 Hz OR 190/380 Volt 50 Hz N/A Eccentric Weight Adjustment N/A 68 lb N/A 69000 lb
B3-3000-3-4 N/A 3,000 lb N/A Low - 1,800 (Max @ 60 Hz) - 1,500 (Max @ 50 Hz) N/A Electric AC - 3 Phase 230/460 Volt 60 Hz OR 190/380 Volt 50 Hz N/A Eccentric Weight Adjustment N/A 128 lb N/A 90000 lb
B3-4000-3-4 N/A 4,000 lb N/A Low - 1,800 (Max @ 60 Hz) - 1,500 (Max @ 50 Hz) N/A Electric AC - 3 Phase 230/460 Volt 60 Hz OR 190/380 Volt 50 Hz N/A Eccentric Weight Adjustment N/A 141 lb N/A 120000 lb
B3-5500-3-4 N/A 5,500 lb N/A Low - 1,800 (Max @ 60 Hz) - 1,500 (Max @ 50 Hz) N/A Electric AC - 3 Phase 230/460 Volt 60 Hz OR 190/380 Volt 50 Hz N/A Eccentric Weight Adjustment N/A 149 lb N/A 165000 lb
B3-7700-4-4 N/A 7,700 lb N/A Low - 1,800 (Max @ 60 Hz) - 1,500 (Max @ 50 Hz) N/A Electric AC - 3 Phase 230/460 Volt 60 Hz OR 190/380 Volt 50 Hz N/A Eccentric Weight Adjustment N/A 236 lb N/A
B3-10000-4-4 N/A 10,000 lb N/A Low - 1,800 (Max @ 60 Hz) - 1,500 (Max @ 50 Hz) N/A Electric AC - 3 Phase 230/460 Volt 60 Hz OR 190/380 Volt 50 Hz N/A Eccentric Weight Adjustment N/A 266 lb N/A
B3-12300-4-4 N/A 12,300 lb N/A Low - 1,800 (Max @ 60 Hz) - 1,500 (Max @ 50 Hz) N/A Electric AC - 3 Phase 230/460 Volt 60 Hz OR 190/380 Volt 50 Hz N/A Eccentric Weight Adjustment N/A 278 lb N/A
B3-16500-5-4 N/A 16,500 lb N/A Low - 1,800 (Max @ 60 Hz) - 1,500 (Max @ 50 Hz) N/A Electric AC - 3 Phase 230/460 Volt 60 Hz OR 190/380 Volt 50 Hz N/A Eccentric Weight Adjustment N/A 442 lb N/A
B3-237-0A-2 N/A 237 lb N/A Moderate - 3,600 (Max @ 60 Hz) - 3,000 (Max @ 50 Hz) N/A Electric AC - 3 Phase 230/460 Volt 60 Hz OR 190/380 Volt 50 Hz N/A Eccentric Weight Adjustment N/A N/A 4740 lb
B3-250-1A-4 N/A 250 lb N/A Low - 1,800 (Max @ 60 Hz) - 1,500 (Max @ 50 Hz) N/A Electric AC - 3 Phase 230/460 Volt 60 Hz OR 190/380 Volt 50 Hz N/A Eccentric Weight Adjustment N/A N/A 7500 lb
1 - 12 of 12 | Results Per Page | View | Unit of Measure
1 
^